| Action |
DEPRECATED |
| action |
DEPRECATED |
| ActivePChangeTolerance |
Required for VOLTWATT |
| Ag |
Gearbox ratio (Default 1/90) |
| allocationfactor |
Allocation factor for allocating loads based on connected kVA at a bus |
| AmpLimit |
Is the current limiter per phase for the IBR when operating in GFM mode |
| AmpLimitGain |
Use it for fine tunning the current limiter when active, by default is 0 |
| amps |
Magnitude of current source, each phase, in Amps |
| Angle |
Phase angle in degrees of first phase |
| angle |
Array of phase angle values, degrees |
| APCFlg |
1 to enable active power control |
| ArGraHiV |
Required for the dynamic reactive current mode (DYNAMICREACCURR), and default... |
| ArGraLowV |
Required for the dynamic reactive current mode (DYNAMICREACCURR), and default... |
| attack_defense |
Define attack and defense: attack_defense = {atk , dfs , atk_time , atk_node... |
| AvgNeutralHeight |
Average height of neutral conductors |
| AvgPhaseHeight |
Average height of phase conductors |
| avgwindowlen |
Required for VOLTVAR mode and VOLTWATT mode, and defaults to 0 seconds (0s) |
| B0 |
Alternate way to specify C0 |
| B1 |
Alternate way to specify C1 |
| b_Curt_Ctrl |
b_Curt_Ctrl:set P curtailment on/off;b_Curt_Ctrl=True: P curtailment will be ... |
| Balanced |
For Model=7, force balanced current only for 3-phase generators |
| band |
Bandwidth in VOLTS for the controlled bus (full bandwidth) |
| bank |
Name of the bank this transformer is part of, for CIM, MultiSpeak, and other ... |
| basefreq |
Base Frequency for ratings |
| baseFreq |
Frequency at which impedances are specified |
| basekv |
Base Source kV, usually phase-phase (L-L) unless positive-sequence or single-... |
| baseMVA |
Base MVA for converting per-unit impedances |
| bp1 |
XYCurve defining the input piece-wise linear block |
| bp2 |
XYCurve defining the output piece-wise linear block |
| Breakertime |
Fixed delay time (sec) added to relay time |
| bus |
Bus connection spec for the active winding (set by wdg property) |
| bus1 |
Bus to which the load is connected |
| Bus1 |
Name of converter bus, containing both AC and DC conductors |
| bus2 |
Name of bus to which 2nd terminal is connected |
| Bus2 |
Name of bus to which 2nd terminal is connected |
| buses |
Use this to specify all the bus connections at once using an array |
| BusH |
Name of High-side(H) bus |
| BusNH |
Name of Neutral bus for H, or first, winding |
| BusNX |
Name of Neutral bus for X, or Second, winding |
| BusX |
Name of Low-side(X) bus, if type=Auto or YY |
| C |
Value of line blocking capacitance in microfarads |
| C0 |
Zero-sequence capacitance, nf per unit length |
| C1 |
Positive-sequence capacitance, nf per unit length |
| C_array |
Array of current (or voltage) values corresponding to time values (see help o... |
| CAIDI |
(Read only) Makes CAIDI result available via return on query (? energymeter |
| capacitor |
Name of Capacitor element which the CapControl controls |
| Capradius |
Equivalent conductor radius for capacitance calcs |
| CC_Switch |
CC_Switch: default value is false |
| Cfactor |
Factor relating average kW to peak kW |
| ChargeTrigger |
Dispatch trigger value for charging the Storage |
| class_class |
An arbitrary integer number representing the class of PVSystem element |
| clear |
{ Yes |
| CLimit |
Current Limit for the UPFC, if the current passing through the UPFC is higher... |
| Cluster_num |
Cluster_num: has to be coincident with Fmonitor attached |
| cmatrix |
Nodal cap |
| cncable |
Code from CNData |
| cncables |
Array of CNData names for use in a cable constants calculation |
| Cogen |
{Yes |
| CombiMode |
Combination of smart inverter functions in which the InvControl will control ... |
| Comm_hide |
Comm_hide={ |
| Comm_node_hide |
Comm_node_hide={ |
| CommDelayVector |
CommDelayVector of this FMonitor |
| CommVector |
CommVector of this FMonitor |
| cond |
Set this = number of the conductor you wish to define |
| conductors |
Array of conductor names for use in line constants calculation |
| conn |
Connection type |
| conns |
Use this to specify all the Winding connections at once using an array |
| ControlMode |
Defines the control mode for the inverter |
| ControlModel |
Integer defining the method for moving across the control curve |
| ControlSignal |
Name of the load shape used for controlling the connection/disconnection of t... |
| Core |
{Shell* |
| Cp |
Turbine performance coefficient (deafult 0 |
| csvfile |
Switch input of growth curve data to a csv file containing (year, mult) point... |
| CSVFile |
File of spectrum points with (harmonic, magnitude-percent, angle-degrees) val... |
| CTPhase |
Number of the phase being monitored for CURRENT control or one of {AVG |
| CTprim |
Rating, in Amperes, of the primary CT rating for which the line amps convert ... |
| CTratio |
Ratio of the CT from line amps to control ampere setting for current and kvar... |
| ctrl_mode |
ctrl mode: /// contrl mode /// ctrl_mode =0; phases = 3; // pos a... |
| cuf |
ARRAY of Capacitance, each phase, for each step, microfarads |
| currents |
Array of Currents (amps) measured by the current sensor |
| CustInterrupts |
(Read only) Makes Total Customer Interrupts value result available via return... |
| CVRcurve |
Curve describing both watt and var factors as a function of time |
| CVRvars |
Percent reduction in reactive power per 1% reduction in voltage from 100% rat... |
| CVRwatts |
Percent reduction in active power per 1% reduction in voltage from 100% rated |
| D |
Damping constant |
| d0 |
Fixed or initial value of the power angle in degrees |
| daily |
LOADSHAPE object name for daily simulations |
| Daily |
LOADSHAPE object to use for daily simulations |
| dblfile |
Switch input of growth curve data to a binary file of doubles containing (yea... |
| DbVMax |
Required for the dynamic reactive current mode (DYNAMICREACCURR), and default... |
| DbVMin |
Required for the dynamic reactive current mode (DYNAMICREACCURR), and default... |
| DeadTime |
Dead time after capacitor is turned OFF before it can be turned back ON |
| debugtrace |
Turn this on to capture the progress of the generator model for each iteratio... |
| Debugtrace |
[Yes |
| DebugTrace |
{Yes/True* |
| Delay |
Time delay, in seconds, from when the control is armed before it sends the sw... |
| delay |
Time delay, in seconds, from when the voltage goes out of band to when tap ch... |
| DelayOFF |
Time delay, in seconds, for control to turn OFF when present state is ON |
| delt0 |
User defined internal simulation step |
| Deltadirection |
{1 or -1} Default is 1: 1-2, 2-3, 3-1 |
| deltaP_Factor |
Required for the VOLTWATT mode |
| DeltaQ_factor |
Convergence parameter; Defaults to 0 |
| deltaQ_Factor |
Required for the VOLTVAR and DYNAMICREACCURR modes |
| DERList |
Alternative to PVSystemList for CIM export and import |
| detailed |
{Yes/True |
| DiaCable |
Diameter over cable; same units as radius; no default |
| DiaIns |
Diameter over insulation layer; same units as radius; no default |
| diam |
Diameter; Alternative method for entering radius |
| DiaShield |
Diameter over tape shield; same units as radius; no default |
| DiaStrand |
Diameter of a concentric neutral strand; same units as core conductor radius;... |
| DischargeTrigger |
Dispatch trigger value for discharging the Storage |
| DispFactor |
Defaults to 1 (disabled) |
| dispmode |
Dispatch mode |
| DispMode |
{DEFAULT |
| dispvalue |
Dispatch value |
| DistReverse |
{Yes/True* |
| DOC_DelayInner |
Trip time delay (sec) for operation in inner region for DOC relay, defined wh... |
| DOC_P1Blocking |
{Yes/True* |
| DOC_PhaseCurveInner |
Name of the TCC Curve object that determines the phase trip for operation in ... |
| DOC_PhaseTripInner |
Multiplier for the "DOC_PhaseCurveInner" TCC curve |
| DOC_TDPhaseInner |
Time dial for "DOC_PhaseCurveInner" TCC curve |
| DOC_TiltAngleHigh |
Tilt angle for high-current trip line |
| DOC_TiltAngleLow |
Tilt angle for low-current trip line |
| DOC_TripSettingHigh |
Resistive trip setting for high-current line |
| DOC_TripSettingLow |
Resistive trip setting for low-current line |
| DOC_TripSettingMag |
Trip setting for current magnitude (defines a circle in the relay characteris... |
| Domain |
It is the domain for which the equation is defined, it can be one of [time*, ... |
| droop |
droop type: integer: 2- Q = kcq_drp2 * (1-v_dg) |
| duty |
LOADSHAPE object name for duty cycle simulations |
| Duty |
LOADSHAPE object to use for duty cycle simulations |
| DutyStart |
Starting time offset [hours] into the duty cycle shape |
| DynaData |
String that gets passed to the user-written dynamics model Edit function |
| DynaDLL |
Name of DLL containing user-written dynamics model for Dynamics-mode simulati... |
| DynamicEq |
Name of the dynamic equation (DynamicExp) for defining the dynamic behavior o... |
| DynOut |
Name of the variables within the Dynamic equation for governing generator dyn... |
| DynReacavgwindowlen |
Required for the dynamic reactive current mode (DYNAMICREACCURR), and default... |
| EarthModel |
Earth model to use for impedance calculations |
| EE |
Eastward Electric field (V/km) |
| EffCurve |
An XYCurve object, previously defined, that describes the PER UNIT efficiency... |
| EGen |
EGen = {kVA_fm, M_fm, D_fm, Tau_fm, Ki_fm,init_time}where equations are:(1):d... |
| Element |
The name of the PD element monitored when operating with reactive power compe... |
| element |
Full object name of the circuit element (typically a line or transformer) to ... |
| ElementList |
Array list of Storage elements to be controlled |
| ElemTableLine |
ElemTableLine of the each node within this cluster |
| emergamps |
Maximum or emerg current |
| emerghkVA |
Emergency (contingency) kVA rating of H winding (winding 1+2) |
| EN |
Northward Electric field (V/km) |
| enabled |
Indicates whether this element is enabled |
| EpsR |
Insulation layer relative permittivity; default is 2 |
| EpsRmedium |
Relative Permittivity of the medium |
| EqDistPhN |
Equivalent distance between phase and neutral conductors |
| EqDistPhPh |
Equivalent distance between phase conductors |
| EventLog |
{Yes/True* |
| expression |
It is the differential expression using OpenDSS RPN syntax |
| faultrate |
Failure rate per year |
| filter |
XYCurve defining the digital filter coefficients (x numerator, y denominator) |
| flrise |
Temperature rise, deg C, for full load |
| forceon |
Forces generator ON despite requirements of other dispatch modes |
| Forecast |
Loadshape object containing daily forecast |
| frequency |
Source frequency |
| fsample |
Sample frequency [Hz} for the digital filter |
| FuelkWh |
Nominal level of fuel for the generator (kWh) |
| FuseCurve |
Name of the TCC Curve object that determines the fuse blowing |
| gen_class |
An arbitrary integer number representing the class of Generator |
| GenList |
Array list of generators to be dispatched |
| geometry |
Geometry code for LineGeometry Object |
| Gmatrix |
Use this to specify a nodal conductance (G) matrix to represent some arbitrar... |
| GMRac |
GMR at 60 Hz |
| GmrStrand |
Geometric mean radius of a concentric neutral strand; same units as core cond... |
| GMRunits |
Units for GMR: {mi |
| Groundcurve |
Name of the TCC Curve object that determines the ground trip |
| GroundDelayed |
Name of the TCC Curve object that determines the Ground Delayed trip |
| GroundFast |
Name of the TCC Curve object that determines the Ground Fast trip |
| GroundInst |
Actual amps for instantaneous ground trip which is assumed to happen in 0 |
| GroundTrip |
Multiplier or actual ground amps (3I0) for the ground TCC curve |
| growth |
Growthshape object name to use for growth factors by years |
| H |
Per unit mass constant of the machine |
| h |
Height of conductor |
| Harm |
ARRAY of harmonics to which each step is tuned |
| harmonic |
Array of harmonic values |
| HeightOffset |
Average Height (or depth) offset to be applied on top of coordinates of geome... |
| HeightUnit |
Height offset Units |
| hour |
Array of hour values |
| hs |
Per-conductor h (height) coordinates (populated from inline cond= blocks) |
| hsrise |
Hot spot temperature rise, deg C |
| hysteresis_offset |
Required for VOLTVAR mode, and defaults to 0 |
| Iacmax |
Maximum value of AC line current, per-unit of nominal |
| Idcmax |
Maximum value of DC current, per-unit of nominal |
| idle |
{Yes |
| idleForward |
{Yes |
| idleReverse |
{Yes |
| imaxpu |
Maximum output current in per-unit of rated; defaults to 1 |
| InhibitTime |
Hours (integer) to inhibit Discharging after going into Charge mode |
| InsLayer |
Insulation layer thickness; same units as radius; no default |
| Int_Duration |
Average annual duration, in hr, of interruptions for head of the meter zone (... |
| Int_Rate |
Average number of annual interruptions for head of the meter zone (source sid... |
| Interpolation |
{AVG* |
| interval |
Time interval for fixed interval data, hrs |
| inversetime |
{Yes |
| irmstau |
Time constant in producing Irms from the PLL; defaults to 0 |
| irradiance |
Get/set the present irradiance value in kW/sq-m |
| Isc1 |
Alternate method of defining source impedance via single-phase fault current ... |
| Isc3 |
Alternate method of defining source impedance via 3-phase fault current (kA) |
| K |
Mvar K factor |
| k |
Number of concentric neutral strands; default is 2 |
| kcd |
kcd: Idi control gain |
| kcq |
kcq: Iqi control gain to delta V |
| kcq_drp2 |
kcq_drp2 |
| Kp |
It is the proportional gain for the PI controller within the inverter |
| kqi |
kqi: Iqi control gain to delta Q |
| Kron |
Kron = Y/N |
| kV |
Nominal rated (1 |
| kv |
Nominal rated (1 |
| kVA |
Specify base Load in kVA (and power factor) |
| kVac |
Nominal AC line-neutral voltage in kV |
| kVAemerg |
Upper limit on kVA load in the zone, Emergency configuration |
| kVAnormal |
Upper limit on kVA load in the zone, Normal configuration |
| kvar |
Base kvar for specifying load as kW & kvar |
| kvarLimit |
Maximum amount of reactive power (kvar) that can be absorved by the UPFC (Def... |
| kvarlimit |
Max kvar to be delivered through the element |
| kvarMax |
Maximum reactive power GENERATION (un-signed, kvar) for the inverter |
| kvarMaxAbs |
Maximum reactive power ABSORPTION (un-signed, kvar) for the inverter |
| kvars |
Array of Reactive power (kvar) measurements at the sensor |
| kVAs |
Use this to specify the kVA ratings of all windings at once using an array |
| kvbase |
Voltage base (kV) for the relay |
| kVDC |
Indicates the rated voltage (kV) at the input of the inverter at the peak of ... |
| kVdc |
Nominal DC voltage in kV |
| KVLL1 |
Optional |
| KVLL2 |
Optional |
| kVs |
Use this to specify the kV ratings of all windings at once using an array |
| kW |
Total base kW for the load |
| kWActual |
(Read only) |
| kWBand |
Bandwidth (kW) of the dead band around the target limit |
| kWBandLow |
Alternative way of specifying the bandwidth |
| kwh |
kWh billed for this period |
| kWhActual |
(Read only) |
| kwhdays |
Length of kWh billing period in days (24 hr days) |
| kWhrated |
Rated Storage capacity in kWh |
| kWhstored |
Present amount of energy stored, kWh |
| kWhTotal |
(Read only) |
| kWLimit |
kW Limit for the monitored element |
| kWneed |
(Read only) |
| kWrated |
kW rating of power output |
| kWs |
Array of Active power (kW) measurements at the sensor |
| kWTarget |
kW/kamps target for Discharging |
| kWTargetLow |
kW/kamps target for Charging |
| kWThreshold |
Threshold, kW, for Follow mode |
| kWTotal |
(Read only) |
| Lamda |
Tip speed ratio (Default 7 |
| Lat1 |
Latitude of Bus1 (degrees) |
| Lat2 |
Latitude of Bus2 (degrees) |
| LCurve |
Name of XYCurve object describing per-unit variation of phase inductance, L=X... |
| LDC_Z |
Z value for Beckwith LDC_Z control option |
| LeadLag |
{Lead |
| length |
Length of line |
| like |
Make like another object, e |
| LimitCurrent |
Limits current magnitude to Vminpu value for both 1-phase and 3-phase PVSyste... |
| linecode |
Name of linecode object describing line impedances |
| LineLosses |
{Yes |
| LineType |
Code designating the type of line |
| LmH |
Inductance, mH |
| load_class |
An arbitrary integer number representing the class of load so that load value... |
| LocalControlList |
Array list of ESPVLControl local controller objects to be dispatched by Syste... |
| LocalControlWeights |
Array of proportional weights corresponding to each ESPVLControl local contro... |
| LocalOnly |
{Yes |
| Lock |
{Yes |
| Lon1 |
Longitude of Bus1 (degrees) |
| Lon2 |
Longitude of Bus2 (degrees) |
| LossCurve |
Name of the XYCurve for describing the losses behavior as a function of the v... |
| Losses |
{Yes |
| LPFTau |
Not required |
| m |
m Exponent for thermal properties in IEEE C57 |
| m0 |
Fixed or initial value of the modulation index |
| Mask |
Mask for adding registers whenever all meters are totalized |
| maxkvar |
Maximum kvar limit for Model = 3 |
| MaxLocalMem |
MaxLocalMem: the max number of local memory siza |
| MaxSlip |
Max slip value to allow |
| MaxTap |
Max per unit tap for the active winding |
| maxtapchange |
Maximum allowable tap change per control iteration in STATIC control mode |
| mean |
Mean of the active power multipliers |
| MemoryMapping |
{Yes |
| Mground |
Ground reach multiplier in per-unit for Distance and TD21 functions |
| MinAmps |
Minimum amps that can sustain a temporary fault |
| minkvar |
Minimum kvar limit for Model = 3 |
| MinTap |
Min per unit tap for the active winding |
| minterval |
Specify fixed interval in MINUTES |
| Mmax |
Maximum value of modulation index |
| Mmin |
Minimum value of modulation index |
| Mode |
Integer used to define the control mode of the UPFC: 0 = Off, 1 = Voltage reg... |
| mode |
Bitmask integer designating the values the monitor is to capture: 0 = Voltage... |
| ModeCharge |
{Loadshape |
| ModeDischarge |
{PeakShave* |
| model |
Integer code for the model to use for load variation with voltage |
| Model |
{Thevenin* |
| monBus |
Name of monitored bus used by the voltage-dependente control modes |
| MonBusesVbase |
Array list of rated voltages of the buses and their nodes presented in the mo... |
| MonitoredObj |
Full object name of the circuit element, typically a line, transformer, load,... |
| MonitoredTerm |
Number of the terminal of the circuit element to which the Fuse is connected |
| MonPhase |
Number of the phase being monitored or one of {AVG |
| monVoltageCalc |
Number of the phase being monitored or one of {AVG |
| Mphase |
Phase reach multiplier in per-unit for Distance and TD21 functions |
| mult |
Array of growth multiplier values, or a text file spec, corresponding to the ... |
| MVA |
MVA rating of electrical machine |
| MVAsc1 |
MVA Short Circuit, 1-phase fault |
| MVAsc3 |
MVA Short circuit, 3-phase fault |
| n |
n Exponent for thermal properties in IEEE C57 |
| N_WTG |
Number of WTG in aggregation |
| name |
Object name |
| nconds |
Number of conductors in this geometry |
| Ndc |
Number of DC conductors |
| neg_seq_46_base_amps |
Base current, Amps, for 46 relay (neg seq current) |
| neg_seq_46_isqt |
Negative Sequence I-squared-t trip value for 46 relay (neg seq current) |
| neutral |
Designates which conductor is the neutral conductor that will be eliminated b... |
| Node_num |
Node_numAssign a node number within a cluster |
| Nodes |
Nodes connected to this FMonitor |
| Normal |
ARRAY of strings {Open |
| normamps |
Normal rated current |
| normhkVA |
Normal maximum kVA rating of H winding (winding 1+2) |
| nphases |
Number of phases in the line this line code data represents |
| npts |
Number of points to expect in subsequent vector |
| NumCust |
Number of customers, this load |
| NumFast |
Number of Fast (fuse saving) operations |
| NumHarm |
Number of frequencies in this spectrum |
| Numsteps |
Number of steps in this capacitor bank |
| NumTaps |
Total number of taps between min and max tap |
| nvariables |
(Int) Number of state variables to be considered in the differential equation |
| OFFsetting |
Value at which the control arms to switch the capacitor OFF |
| ONsetting |
Value at which the control arms to switch the capacitor ON (or ratchet up a s... |
| ONtime |
Time (sec) at which the fault is established for time varying simulations |
| option |
Enter a string ARRAY of any combination of the following |
| overtrip |
Trip setting (high value) for Generic relay variable |
| Overvoltcurve |
TCC Curve object to use for overvoltage relay |
| P |
Number of pole pairs of the induction generator (Default 2) |
| P_TCurve |
An XYCurve object, previously defined, that describes the PV array PER UNIT P... |
| P_Mode |
0 = real Power controlled by each p_ref on each DG1 = real Power on MeteredEl... |
| P_ref1kW |
P_ref1kW = 10, goes to P_ref1, unit kW, 1st phase set power |
| P_ref2kW |
P_ref2kW = 10, goes to P_ref2, unit kW, 2nd phase set power |
| P_ref3kW |
P_ref3kW = 10, goes to P_ref3, unit kW, 3rd phase set power |
| P_refkW |
P_refkW = 10, goes to P_ref |
| P_Sensor |
P_SensorEnable power sensor |
| P_trans_ref |
P_trans_ref: P ref value for metered element(unit kW) |
| Pacref |
Reference total AC real power, Watts |
| Parallel |
{Yes |
| Pbase |
Base P value for normalization |
| PbiaskW |
Pbias = -0 |
| pct_46_pickup |
Percent pickup current for 46 relay (neg seq current) |
| pct_47_pickup |
Percent voltage pickup for 47 relay (Neg seq voltage) |
| pct_Charge |
Charging rate (input power) in percentage of rated kW |
| pct_Cutin |
% cut-in power -- % of kVA rating of inverter |
| pct_Cutout |
% cut-out power -- % of kVA rating of inverter |
| pct_Discharge |
Discharge rate (output power) in percentage of rated kW |
| pct_EffCharge |
Percentage efficiency for CHARGING the Storage element |
| pct_EffDischarge |
Percentage efficiency for DISCHARGING the Storage element |
| pct_Error |
Assumed percent error in the measurement |
| pct_Fuel |
Current amount of fuel available in percentage of FuelkWh (0-100) |
| pct_Idlingkvar |
Deprecated |
| pct_IdlingkW |
Percentage of rated kW consumed by idling losses |
| pct_imag |
Percent magnetizing current |
| pct_kWBand |
Bandwidth (% of Target kW/kamps) of the dead band around the kW/kamps target ... |
| pct_kWBandLow |
Bandwidth (% of kWTargetLow) of the dead band around the kW/kamps low target ... |
| pct_kWrated |
Upper limit on active power as a percentage of kWrated |
| pct_loadloss |
Percent load loss at full load |
| pct_mag |
Array of magnitude values, assumed to be in PERCENT |
| pct_mean |
Percent mean value for load to use for monte carlo studies if no loadshape is... |
| pct_noloadloss |
Percent no load losses at rated excitation voltage |
| pct_perm |
Percent of failures that become permanent |
| pct_PminkvarMax |
Minimum active power as percentage of Pmpp that allows the inverter to produc... |
| pct_PminNoVars |
Minimum active power as percentage of Pmpp under which there is no vars produ... |
| pct_Pmpp |
Upper limit on active power as a percentage of Pmpp |
| pct_R |
Equivalent percent internal resistance, ohms |
| pct_R1 |
Optional |
| pct_R2 |
Optional |
| pct_RateCharge |
Sets the kW charging rate in % of rated capacity for each element of the flee... |
| pct_RatekW |
Sets the kW discharge rate in % of rated capacity for each element of the fle... |
| pct_Reserve |
Reserve level in percentage of FuelkWh (0-100) |
| pct_reserve |
Percentage of rated kWh Storage capacity to be held in reserve for normal ope... |
| pct_Rs |
Use this property to specify all the winding ac %resistances using an array |
| pct_SeriesRL |
Percent of load that is series R-L for Harmonic studies |
| pct_stddev |
Percent Std deviation value for load to use for monte carlo studies if no loa... |
| pct_stored |
Present amount of energy stored, % of rated kWh |
| pct_X |
Equivalent percent internal reactance, ohms |
| pctMinkvar |
For PF control option, min percent of total bank kvar at which control will c... |
| pctperm |
Percent of failures that become permanent |
| pd |
Air density in kg/m3 (Default 1 |
| peakcurrent |
ARRAY of current magnitudes representing the peak currents measured at this l... |
| pf |
Load power factor |
| PF |
WindGen power factor |
| Pfctr1 |
Pfctr1 = 0 |
| Pfctr2 |
Pfctr2 = 1, 1 by default, see PmppkW |
| Pfctr3 |
Pfctr3 = 1, 1 by default, see PmppkW |
| Pfctr4 |
Pfctr4= 1, 1 by default, see PmppkW |
| Pfctr5 |
Pfctr5 =1, 1 by default, see PmppkW |
| Pfctr6 |
Pfctr6 = 1, 1 by default, see PmppkW |
| PFPriority |
{Yes/No*/True/False} Set inverter to operate with PF priority when in constan... |
| Phasecurve |
Name of the TCC Curve object that determines the phase trip |
| PhaseDelayed |
Name of the TCC Curve object that determines the Phase Delayed trip |
| PhaseFast |
Name of the TCC Curve object that determines the Phase Fast trip |
| PhaseInst |
Actual amps for instantaneous phase trip which is assumed to happen in 0 |
| phases |
Number of Phases, this load |
| PhaseTrip |
Multiplier or actual phase amps for the phase TCC curve |
| PhaseVoltageReport |
{Yes |
| PITol |
It is the tolerance (%) for the closed loop controller of the inverter |
| PLoss |
Name of the XYCurve object describing the active power losses in pct versus t... |
| Pmax |
kW value at the time of max power |
| PmaxkW |
PmaxkW = 100, goes to Pmax, unit kW, set max active power output; Operation l... |
| PminkW |
PminkW = 10, goes to Pmin, unit kW; Operation limit of active power for DG |
| Pmpp |
Get/set the rated max power of the PV array for 1 |
| PmppkW |
PmppkW = 100, goes to Pmpp, unit kW, input Pmpp to calculate kW; kW := (Pmpp... |
| Pmult |
Synonym for "mult" |
| Points |
One way to enter the points in a curve |
| ppct |
Steady-state operating output, in percent of rated |
| ppm_antifloat |
ppm (parts per million) anti-float factor |
| PPolar |
{Yes/True |
| PQCSVFile |
Switch input to a CSV text file containing (active, reactive) power (P, Q) mu... |
| PQpriority |
PQpriority, goes to PQpriority, define how to set Qmax |
| prated |
Total rated power, in Watts |
| PreferQ |
{Yes/True* |
| price |
Array of Price values |
| Pss |
Steady state output real power |
| PTPhase |
Number of the phase being monitored for VOLTAGE control or one of {AVG |
| PTphase |
For multi-phase transformers, the number of the phase being monitored or one ... |
| PTratio |
Ratio of the PT that converts the monitored voltage to the control voltage |
| ptratio |
Ratio of the PT that converts the controlled winding voltage to the regulator... |
| pu |
Per unit of the base voltage that the source is actually operating at |
| puRr |
Per unit rotor resistance |
| puRs |
Per unit stator resistance |
| puXharm |
Special reactance, pu (based on kVA, kV properties), for the series impedance... |
| puXm |
Per unit magnetizing reactance |
| puXr |
Per unit rotor leakage reactance |
| puXs |
Per unit stator leakage reactance |
| puZ0 |
Zero-sequence impedance in per-unit |
| puZ1 |
Positive-sequence impedance in per-unit on source kVA base |
| puZ2 |
Negative-sequence impedance in per-unit |
| puZideal |
Per-unit series impedance when Model=Ideal |
| pvfactor |
Deceleration factor for P-V generator model (Model=3) |
| PVSystemList |
Array list of PVSystem objects to be dispatched by a Local Controller |
| PVSystemWeights |
Array of proportional weights corresponding to each PVSystem in the PVSystemL... |
| pyScript |
This is the path to the controller script, it is expected to be a python scri... |
| Q_ref1kVAr |
Q_ref1kVAr=10 |
| Q_ref2kVAr |
Q_ref2kVAr=10 |
| Q_ref3kVAr |
Q_ref3kVAr=10 |
| Q_refkVAr |
Q_refkVAr=10 |
| Qacref |
Reference total AC reactive power, Vars |
| Qbase |
Base Q value for normalization |
| Qbias |
Equilibrium per-unit reactive power when V=Vreg; defaults to 0 |
| QFlg |
1 to enable reactive power and voltage control |
| Qmax |
kvar value at the time of max kW power |
| QmaxLag |
Limit on lagging (capacitive) reactive power injection, in per-unit of base k... |
| QmaxLead |
Limit on leading (inductive) reactive power injection, in per-unit of base kv... |
| QMode |
Q control mode (0:Q, 1:PF, 2:VV) |
| qmult |
Array of multiplier values for reactive power (Q) |
| Qss |
Steady state output reactive power |
| QV_flag |
QV_flag : 0-Q_ref mode; 1- V_ref mode |
| R |
Resistance of line, ohms of impedance in series with GIC voltage source |
| r |
Resistance, each phase, ohms |
| r0 |
Zero-sequence Resistance, ohms per unit length |
| R0 |
Zero-sequence resistance, ohms |
| R1 |
Resistance, each phase, ohms for H winding, (Series winding, if Auto) |
| r1 |
Positive-sequence Resistance, ohms per unit length |
| R2 |
Resistance, each phase, ohms for X winding, (Common winding, if Auto) |
| Rac |
AC resistance (ohms) for the converter transformer, plus any series reactors |
| Rad |
Rotor radius in meters (Default 40) |
| radius |
Outside radius of conductor |
| radunits |
Units for outside radius: {mi |
| RatedCurrent |
Multiplier or actual phase amps for the phase TCC curve |
| RateofChangeMode |
Required for VOLTWATT and VOLTVAR mode |
| Ratings |
An array of ratings to be used when the seasonal ratings flag is True |
| RCurve |
Name of XYCurve object describing per-unit variation of phase resistance, R, ... |
| Rdc |
dc Resistance, ohms per unit length (see Runits) |
| Rdcohms |
Winding dc resistance in OHMS |
| RdcOhms |
Winding dc resistance in OHMS |
| RecloseIntervals |
Array of reclose intervals |
| reduce |
{Yes |
| refkv |
Base Voltage expected at the output of the UPFC"refkv=0 |
| refkv2 |
Base Voltage expected at the output of the UPFC for control modes 4 and 5 |
| RefReactivePower |
Required for any mode that has VOLTVAR, DYNAMICREACCURR and WATTVAR |
| Refuel |
Boolean value to manually refuel the generator when needed |
| RelWeight |
Relative weighting factor for reliability calcs |
| RemotePTRatio |
PT ratio required to convert actual voltage at the remote bus to control volt... |
| repair |
Hours to repair |
| Reset |
{Yes |
| ResetLevel |
The level of charge required for allowing the storage to discharge again afte... |
| residual |
{Yes/True |
| rev_Z |
Reverse Z value for Beckwith LDC_Z control option |
| revband |
Bandwidth for operating in the reverse direction |
| revDelay |
Time Delay in seconds for executing the reversing action once the threshold f... |
| reversible |
{Yes |
| revNeutral |
{Yes |
| revR |
R line drop compensator setting for reverse direction |
| revThreshold |
kW reverse power threshold for reversing the direction of the regulator |
| revvreg |
Voltage setting in volts for operation in the reverse direction |
| revX |
X line drop compensator setting for reverse direction |
| Rg |
Carson earth return resistance per unit length used to compute impedance valu... |
| rho |
Earth resitivity used to compute earth correction factor |
| RiseFallLimit |
Not required |
| rmatrix |
Resistance matrix, lower triangle, ohms per unit length |
| Rmatrix |
Resistance matrix, lower triangle, ohms at base frequency |
| rmsmode |
True if only Hz is used to represent a phase-locked loop (PLL), ignoring the ... |
| Rneut |
Neutral resistance of wye-connected load in actual ohms |
| Rp |
Resistance in parallel with R and X (the entire branch) |
| Rstrand |
AC resistance of a concentric neutral strand; same units as core conductor re... |
| Rthev |
per unit Thevenin equivalent R |
| Runits |
Length units for resistance: ohms per {mi |
| SafeMode |
(Read only) Indicates whether the inverter entered (Yes) or not (No) into Saf... |
| SafeVoltage |
Indicates the voltage level (%) respect to the base voltage level for which t... |
| SAIDI |
(Read only) Makes SAIDI result available via return on query (? energymeter |
| SAIFI |
(Read only) Makes SAIFI result available via return on query (? energymeter |
| SAIFIkW |
(Read only) Makes SAIFIkW result available via return on query (? energymeter |
| scantype |
{pos* |
| ScanType |
{pos* |
| Seasons |
Defines the number of ratings to be defined for the wire, to be used only whe... |
| SeasonTargets |
An array of doubles specifying the targets to be used during a QSTS simulatio... |
| SeasonTargetsLow |
An array of doubles specifying the targets to be used during a QSTS simulatio... |
| SemiconLayer |
{Yes/True |
| SeqLosses |
{Yes |
| sequence |
{pos* |
| Sequence |
{pos* |
| ShaftData |
String that gets passed to user-written shaft dynamic model |
| ShaftModel |
Name of user-written DLL containing a Shaft model |
| Shots |
Total Number of fast and delayed shots to lockout |
| SimMechFlg |
1 to simulate mechanical system |
| sinterval |
Specify fixed interval in SECONDS |
| Slip |
Initial slip value |
| SlipOption |
Option for slip model |
| Slope |
Per-unit reactive power injection / per-unit voltage deviation from Vreg; def... |
| sngfile |
Switch input of growth curve data to a binary file of singles containing (yea... |
| spacing |
Reference to a LineSpacing for use in a line constants calculation |
| spectrum |
Name of harmonic current spectrum for this load |
| State |
{idling |
| states |
ARRAY of integers {1 |
| status |
Load status |
| stddev |
Standard deviation of active power multipliers |
| StorageList |
Array list of Storage objects to be dispatched by Local Controller |
| StorageWeights |
Array of proportional weights corresponding to each Storage object in the Sto... |
| sub |
={Yes |
| subname |
Substation Name |
| Switch |
Designates this line as a switch for graphics and algorithmic purposes |
| SwitchedObj |
Name of circuit element switch that the Fuse controls |
| SwitchedTerm |
Number of the terminal of the controlled element in which the switch is contr... |
| T_array |
Array of time values in sec |
| T_intvl_smpl |
T_intvl_smpl: The imformation of each agent will be sampled at each T_comm ti... |
| tap |
Per unit tap that this winding is on |
| tapdelay |
Delay in sec between tap changes |
| TapeLap |
Tape Lap in percent; default 20 |
| TapeLayer |
Tape shield thickness; same units as radius; no default |
| TapNum |
An integer number indicating the tap position that the controlled transformer... |
| taps |
Use this to specify the per-unit tap positions of all windings at once |
| tapwinding |
Winding containing the actual taps, if different than the WINDING property |
| Tdaily |
Temperature shape to use for daily simulations |
| TDGrDelayed |
Time dial for Ground Delayed trip curve |
| TDGrFast |
Time dial for Ground Fast trip curve |
| TDGround |
Time dial for Ground trip curve |
| Tdn |
Duration, hrs, of downramp part for SCHEDULE mode |
| TDPhase |
Time dial for Phase trip curve |
| TDPhDelayed |
Time dial for Phase Delayed trip curve |
| TDPhFast |
Time dial for Phase Fast trip curve |
| Tduty |
Temperature shape to use for duty cycle dispatch simulations |
| temp |
Array of temperature values |
| Temperature |
Get/set the present Temperature (deg C) for the P-T curve |
| temporary |
{Yes |
| terminal |
Number of the terminal of the circuit element to which the CapControl is conn... |
| Terminal |
Number of the terminal of the circuit element to which the ESPVLControl contr... |
| TFlat |
Duration, hrs, of flat part for SCHEDULE mode |
| thermal |
Thermal time constant of the AutoTrans in hours |
| three_phase_losses |
{Yes |
| TimeChargeTrig |
Time of day in fractional hours (0230 = 2 |
| TimeChargeTrigger |
Default time of day (hr) for initiating charging in Time control mode |
| TimeDischargeTrigger |
Default time of day (hr) for initiating Discharging of the fleet |
| Tol1 |
Tolerance in pu for the series PI controllerTol1=0 |
| Total_Clusters |
Total_Clusters |
| transformer |
Name of Transformer or AutoTrans element to which the RegControl is connected |
| Tresponse |
Open-loop response time for changes in Q |
| tscable |
Code from TSData |
| tscables |
Array of TSData names for use in a cable constants calculation |
| Tup |
Duration, hrs, of upramp part for SCHEDULE mode |
| Tyearly |
Temperature shape to use for yearly simulations |
| Type |
Type of transformer: {GSU* |
| type |
{Current |
| undertrip |
Trip setting (low value) for Generic relay variable |
| Undervoltcurve |
TCC Curve object to use for undervoltage relay |
| units |
Length Units |
| up_dly |
up_dly: delay time to upper level |
| UPFCList |
The list of all the UPFC devices to be controlled by this controller, If left... |
| UseActual |
{Yes |
| UseFuel |
Activates the use of fuel for the operation of the generator |
| UserData |
String that gets passed to user-written model |
| UserModel |
Name of DLL containing user-written model for Dynamics studies |
| V_ref1kVLN |
V_ref1kVLN = 2 |
| V_ref2kVLN |
V_ref2kVLN = 2 |
| V_ref3kVLN |
V_ref3kVLN = 2 |
| V_refkVLN |
V_refkVLN = 2 |
| V_Sensor |
V_SensorEnable voltage sensor |
| Vacref |
Reference AC line-to-neutral voltage, RMS Volts |
| var |
(String) Activates the state variable using the given name |
| VarChangeTolerance |
Required for VOLTVAR and DYNAMICREACCURR modes |
| VarCurve |
Optional |
| VarFollowInverter |
Boolean variable (Yes |
| Variable |
Name of variable in PC Elements being monitored |
| varidx |
(Int) read-only, returns the index of the active state variable |
| varnames |
([String]) Array of strings with the names of the state variables |
| VbaseLosses |
{Yes |
| VBus |
Name of bus to use for voltage override function |
| VCutIn |
Cut-in speed for the wind generator (m/s - default 5) |
| VCutOut |
Cut-out speed for the wind generator (m/s - default 23) |
| Vdcref |
Reference DC voltage, Volts |
| VHLimit |
High limit for the voltage at the input of the UPFC, if the voltage is above ... |
| VIPolar |
{Yes/True |
| virtual_ld_node |
which node talks to upper level |
| vlimit |
Voltage Limit for bus to which regulated winding is connected |
| VLLimit |
low limit for the voltage at the input of the UPFC, if voltage is below this ... |
| Vlowpu |
Per unit voltage at which the model switches to constant Z model (model=2) |
| Vmax |
Maximum voltage, in volts, above which control is forced ON regardless of con... |
| Vmaxpu |
Maximum per unit voltage for which the MODEL is assumed to apply |
| Vmin |
Minimum voltage, in volts, below which control is forced OFF regardless of co... |
| Vminemerg |
Minimum per unit voltage for load UE evaluations, Emergency limit |
| Vminnorm |
Minimum per unit voltage for load EEN evaluations, Normal limit |
| Vminpu |
Minimum per unit voltage for which the MODEL is assumed to apply |
| Volt_limits_pu |
Volt_limits_pu: exmaple "Volt_limits_pu={a0,a1, a2}"a0: the phase number, 0 m... |
| Volt_Trhd |
Volt_Trhd |
| voltage_curvex_ref |
Required for VOLTVAR and VOLTWATT modes, and defaults to rated |
| VoltageChangeTolerance |
Defaults to 0 |
| VoltOverride |
{Yes |
| Volts |
Voltage magnitude, in volts, of the GIC voltage induced across this line |
| voltwatt_curve |
Required for VOLTWATT mode |
| voltwattCH_curve |
Required for VOLTWATT mode for Storage element in CHARGING state |
| VoltwattYAxis |
Required for VOLTWATT mode |
| VpqMax |
Maximum voltage (in volts) delivered by the series voltage source (Default = ... |
| Vpu |
Per Unit voltage set point for Model = 3 |
| vrated |
Rated line-to-line voltage, in Volts |
| Vreg |
Per-unit voltage at which reactive power is zero; defaults to 1 |
| vreg |
Voltage regulator setting, in VOLTS, for the winding being controlled |
| VregMax |
Upper limit on adaptive Vreg; defaults to 1 |
| VregMin |
Lower limit on adaptive Vreg; defaults to 0 |
| VregTau |
Time constant for adaptive Vreg |
| vrmstau |
Time constant in sensing Vrms for the PLL; defaults to 0 |
| VscMode |
Control Mode (Fixed |
| Vsetpoint |
Required for Active Voltage Regulation (AVR) |
| Vss |
Steady state voltage magnitude |
| VV_Curve |
Name of the XY curve defining the control curve for implementing Vol-var cont... |
| VV_RefReactivePower |
Deprecated, use RefReactivePower instead |
| vvc_curve1 |
Required for VOLTVAR mode |
| vwind |
Wind speed in m/s |
| wattpf_curve |
Required for WATTPF mode |
| WattPriority |
{Yes/No*/True/False} Set inverter to watt priority instead of the default var... |
| wattvar_curve |
Required for WATTVAR mode |
| wdg |
Set this = to the number of the winding you wish to define |
| WdgCurrents |
(Read only) Makes winding currents available via return on query |
| Weight |
Weighting factor: Default is 1 |
| Weights |
Array of proportional weights corresponding to each Storage element in the El... |
| winding |
Number of the winding of the transformer element that the RegControl is monit... |
| windings |
Number of windings, this AutoTrans |
| wire |
Code from WireData |
| wires |
Array of WireData names for use in an overhead line constants calculation |
| X |
Reactance at base frequency, ohms |
| x |
x coordinate |
| x0 |
Zero-sequence Reactance, ohms per unit length |
| X0 |
Zero-sequence reactance, ohms |
| x0r0 |
Zero-sequence X/R ratio |
| x1 |
Positive-sequence Reactance, ohms per unit length |
| X1 |
Positive-sequence reactance, ohms |
| X12 |
Alternative to XHL for specifying the percent reactance from winding 1 to win... |
| X13 |
Alternative to XHT for specifying the percent reactance from winding 1 to win... |
| x1r1 |
Positive-sequence X/R ratio |
| X23 |
Alternative to XLT for specifying the percent reactance from winding 2 to win... |
| Xac |
AC reactance (ohms) for the converter transformer, plus any series reactors |
| Xarray |
Alternate way to enter X values |
| Xd |
Per unit synchronous reactance of machine |
| Xdp |
Per unit transient reactance of the machine |
| Xdpp |
Per unit subtransient reactance of the machine |
| xfkVA |
Rated kVA of service transformer for allocating loads based on connected kVA ... |
| XfmrCode |
Name of a library entry for transformer properties |
| XfmrLosses |
{Yes |
| Xg |
Carson earth return reactance per unit length used to compute impedance value... |
| XHL |
Percent reactance, H-L (winding 1 to winding 2) |
| Xhl |
Use this to specify the percent reactance, H-L (winding 1 to winding 2) |
| XHT |
Use this to specify the percent reactance, H-T (winding 1 to winding 3) |
| Xht |
Use this to specify the percent reactance, H-T (winding 1 to winding 3) |
| XHX |
Use this to specify the percent reactance, H-L (winding 1 to winding 2) |
| XL |
ARRAY of series inductive reactance(s) in each phase (line) for filter, ohms ... |
| XLT |
Percent reactance, L-T (winding 2 to winding 3) |
| Xlt |
Use this to specify the percent reactance, L-T (winding 2 to winding 3) |
| xmatrix |
Reactance matrix, lower triangle, ohms per unit length |
| Xmatrix |
Reactance matrix, lower triangle, ohms at base frequency |
| Xneut |
Neutral reactance of wye-connected load in actual ohms |
| XRConst |
={Yes |
| XRdp |
X/R ratio for Xdp property for FaultStudy and Dynamic modes |
| XRharm |
X/R ratio of the special harmonics mode reactance specified by the puXHARM pr... |
| Xs |
Reactance of the series transformer of the UPFC, ohms (default=0 |
| xs |
Per-conductor x coordinates (populated from inline cond= blocks) |
| Xscale |
Scale X property values (in/out) by this factor |
| XSCarray |
Use this to specify the percent reactance between all pairs of windings as an... |
| Xscarray |
Percent reactance between all pairs of windings as an array |
| Xshift |
Shift X property values (in/out) by this amount of offset |
| Xthev |
per unit Thevenin equivalent X |
| XXT |
Use this to specify the percent reactance, L-T (winding 2 to winding 3) |
| y |
Enter a value and then retrieve the interpolated X value from the X property |
| Yarray |
Alternate way to enter Y values |
| year |
Array of year values, or a text file spec, corresponding to the multipliers |
| yearly |
LOADSHAPE object name for yearly simulations |
| Yearly |
LOADSHAPE object to use for yearly simulations |
| Yscale |
Scale Y property values (in/out) by this factor |
| Yshift |
Shift Y property values (in/out) by this amount of offset |
| Z |
Alternative way of defining R and X properties as a complex array |
| Z0 |
Zero-sequence impedance, ohms, as a 2-element array [R, X] |
| Z0ang |
Zero sequence reach impedance angle in degrees for Distance and TD21 function... |
| Z0mag |
Zero sequence reach impedance in primary ohms for Distance and TD21 functions |
| Z1 |
Positive-sequence impedance, ohms, as a 2-element array [R, X] |
| Z1ang |
Positive sequence reach impedance angle in degrees for Distance and TD21 func... |
| Z1mag |
Positive sequence reach impedance in primary ohms for Distance and TD21 funct... |
| Z2 |
Negative-sequence impedance, ohms, as a 2-element array [R, X] |
| ZIPV |
Array of 7 coefficients for ZIP load model |
| Zonelist |
ARRAY of full element names for this meter's zone |