Skip to content

Slot: Pmpp

Get/set the rated max power of the PV array for 1.0 kW/sq-m irradiance, kW.

URI: dss:Pmpp

Applicable Classes

Name Description Modifies Slot
Pvsystem A Pvsystem object in OpenDSS representing a photovoltaic generator with inver... no

Properties

Type and Range

Property Value
Range Float
Domain Of Pvsystem

Cardinality and Requirements

Property Value
### Slot Characteristics
Property Value
Owner Pvsystem

Comments

  • Import: PhotoVoltaicUnit.maxP = ActivePower(Pmpp, 'kW'). Export: Pmpp = maxP.to('kW'). CIM stores in W (SI base).

Identifier and Mapping Information

Annotations

property value
order 5

Schema Source

  • from schema: https://gridappsd.github.io/dss-graph/opendss

Mappings

Mapping Type Mapped Value
self dss:Pmpp
native dss:Pmpp
exact cim:PowerElectronicsUnit.maxP

LinkML Source

name: Pmpp
annotations:
  order:
    tag: order
    value: 5
description: Get/set the rated max power of the PV array for 1.0 kW/sq-m irradiance,
  kW.
comments:
- 'Import: PhotoVoltaicUnit.maxP = ActivePower(Pmpp, ''kW''). Export: Pmpp = maxP.to(''kW'').
  CIM stores in W (SI base).'
from_schema: https://gridappsd.github.io/dss-graph/opendss
exact_mappings:
- cim:PowerElectronicsUnit.maxP
rank: 1000
owner: Pvsystem
domain_of:
- Pvsystem
range: float
required: false